Installing a magnetic starter




















Reversing starters switch the shaft rotation of a 3-phase motor. This action happens because of the interchanging any two-line conductors that supply the motor load. A reversing magnetic motor starter has a forward and a reverse starter. It also has electrical and mechanical interlocks that ensure only the forward or the reverse starter can be engaged at once. Motor starters are special-purpose electrical devices designed to handle the high electrical current that motors draw momentarily when they are started from standstill while still protecting the motors from the excessive heat of overloads during regular operation.

Starting current can be several times what the motor draws at its operating speed. If just a fuse or circuit breaker was used, that device would blow or trip with each start. If the motor were to jam—a so-called locked-rotor scenario—it would draw this same inrush current continuously.

In this case, the overload relays would heat beyond the time allotted for normal momentary inrush levels and drop out the switch or contactor and thus the motor. Magnetic motor starters are often used for motors that draw several horsepowers or higher. Examples include woodworking machines such as cabinet saws or shapers. Machines with smaller loads, including most handheld tools typically use only a switch instead of a motor starter.

Magnetic starters are stock components for numerous machines, and aftermarket starters are also used as replacement components or for retrofitting older machines. They are used in across-the-line applications and as reduced voltage starters for single- and three-phase motors.

Motor starters are available as open configurations that are installed in control panels, or they can be standalone units with enclosures, either NEMA or IEC certified. NEMA standard sizes range from 00 to 9 to cover the range of motor sizes beginning around 1. This button is characterized by the constantly open contacts. The second button is red and constantly closed contacts. During the connection of the thermal relay must be remembered that using the power contacts are switching on and off phases.

Zeroes that come and depart, as well as conductors that are grounded, between a need to connect to the field terminal block. At the same time, without fail, the starter needs to depart. Switching of these devices is not possible. To produce the connection of the coil, the magnitude of the operating voltage which is Volts, you need to take zero from the terminals and connect it to the circuit which is intended for operation of the starter.

With the help of additional contacts is support for the coil, and blocking of erroneous inclusions. The most often used scheme, which requires the use of a single actuator.

This is due to its simplicity, which allows to cope with it even novice to master. To build the magnetic starter requires the use of three-core cable, which is applied to the buttons, and one pair of contacts which are open well. When using coil Volts, you must connect the wires red or black. When using the coil Volts is used of opposite phase. The fourth pair free in this scheme used as a block contact.

Three pairs of power contacts are included along with this free pair. The location of all the conductors is made at the top. In that case, if there are two additional conductor, they are placed on the side. Power contacts of the starter is characterized by the presence of three phases.

Rate 0. Chirstoph, There is another issuse. Regards, Asad. Suggestion To thank Quote Answer. Rate 1. If the Starter first installed without the help the download the complete starter setup again included the helpfiles and start the setup again. In the setup then you can select that only the help should be installed.

Where I can find complete version? Hello, all Volumes from here! Then you must unpack all volumes in the same directory and then install. This contribution was helpful to 1 thankful Users azzy9. Im still not able to install HELP. See the Attachment. This contribution was helpful to 1 thankful Users Hasse Toombs Posts: 91 Rating: 4. ChristophD Hello, then start the setup.



0コメント